In rare circumstances, a Processing Unit remains in UNDEPLOYED state although all instances have terminated

Description

A Processing Unit that has been undeployed remains in an UNDEPLOYED state although all instances have terminated. This is caused by one of the managers not being in sync with the others in order to get the event notifications.

A workaround would be to restart one of the managers that is out of sync.

Workaround

restart of out of sync manager

Acceptance Test

Added reproduction test to sgtest suite

Status

Assignee

Meron Avigdor

Reporter

Meron Avigdor

Labels

None

Priority

Medium

SalesForce Case ID

12211

Fix versions

Commitment Version/s

None

Due date

None

Product

XAP

Edition

Premium

Platform