Uploaded image for project: 'InsightEdge Platform'
  1. GS-13751

After fail-over more instances of an PUI than allowed by the SLA where deployed

    Details

    • Type: Bug
    • Status: Open
    • Priority: Medium
    • Resolution: Unresolved
    • Affects versions: None
    • Fix versions: None
    • Labels:
    • Platform:
      All
    • Sprint:
    • Edition:
      Open Source

      Description

      PUI was deployed by tow managers at the same time. resulting in 2 instances on the same pid.
      ## LC3-LXMSS-02
      2018-11-08T11:20:26.921+0100 INFO LC3-LXMSS-02/MANAGER P9820/T87 SPACE/ProvisionPool:1541505988866-6/provision Allocated processing unit instance [ps-b2bua-adapter [1]] on [GSC pid[9016] host[LC3-LXMSS-02/10.31.204.154] service-id[330dd185-fb51-466f-852e-58eb6b450586]]

      ## LC3-LXBMS-02
      2018-11-08T11:20:16.429+0100 INFO LC3-LXBMS-02/MANAGER P11672/T106 SPACE/ProvisionPool:1541665121214-0/provision Allocated processing unit instance [ps-b2bua-adapter [2]] on [GSC pid[9016] host[LC3-LXMSS-02/10.31.204.154] service-id[330dd185-fb51-466f-852e-58eb6b450586]]

      SLA is:max-instances-per-machine="1"

      -<os-sla:sla number-of-instances="2" max-instances-per-machine="1">


      -<os-sla:requirements>

      <os-sla:zone name="FRQ_PS_ADAPTER"/>

      <os-sla:zone name="MSS"/>

      </os-sla:requirements>

      </os-sla:sla>